microfluidic switching valve Search Results


94
Elveflow Inc microfluidic valve control matrix
The Module-Fluidic generates the desired concentration profile that enables downstream <t>microfluidic</t> devices’ function.
Microfluidic Valve Control Matrix, supplied by Elveflow Inc, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/microfluidic valve control matrix/product/Elveflow Inc
Average 94 stars, based on 1 article reviews
microfluidic valve control matrix - by Bioz Stars, 2026-05
94/100 stars
  Buy from Supplier

90
LabSmith Inc microfluidic switching valve
The Module-Fluidic generates the desired concentration profile that enables downstream <t>microfluidic</t> devices’ function.
Microfluidic Switching Valve, supplied by LabSmith Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/microfluidic switching valve/product/LabSmith Inc
Average 90 stars, based on 1 article reviews
microfluidic switching valve - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

90
FLUIGENT Inc m-switch 10-to-1 microfluidic valve
The Module-Fluidic generates the desired concentration profile that enables downstream <t>microfluidic</t> devices’ function.
M Switch 10 To 1 Microfluidic Valve, supplied by FLUIGENT Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/m-switch 10-to-1 microfluidic valve/product/FLUIGENT Inc
Average 90 stars, based on 1 article reviews
m-switch 10-to-1 microfluidic valve - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

90
MicroFluidic Systems switches and valves
The Module-Fluidic generates the desired concentration profile that enables downstream <t>microfluidic</t> devices’ function.
Switches And Valves, supplied by MicroFluidic Systems, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/switches and valves/product/MicroFluidic Systems
Average 90 stars, based on 1 article reviews
switches and valves - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

N/A
The RVM microfluidics rotary Switch valve is a precise OEM low-pressure electric rotary valve designed for automated microfluidic applications. The RVM microfluidics rotary valve series, renowned for its small channels and ultra-precise positioning system, offers
  Buy from Supplier

Image Search Results


The Module-Fluidic generates the desired concentration profile that enables downstream microfluidic devices’ function.

Journal: Micromachines

Article Title: Module-Fluidics: Building Blocks for Spatio-Temporal Microenvironment Control

doi: 10.3390/mi13050774

Figure Lengend Snippet: The Module-Fluidic generates the desired concentration profile that enables downstream microfluidic devices’ function.

Article Snippet: All the valves are controlled by a microfluidic valve control matrix (MUX QUAKE VALVE, Elveflow) with sixteen independent pressure outlets that can provide a constant pressure input when they are switched on.

Techniques: Concentration Assay

Structures of the Spatio-Temporal Concentration Controller. ( A ) 3D structure of Signal generator (Oscillator) and Module Connector (Integrator), the Oscillator consists of three layers, the PDMS structure layer has flow channels patterned. The channel is molded using positive photo resist which produces a semi-cylindrical cross-section for complete sealing of the micro valve. The second layer is a thin PDMS membrane with controlling valves when the air pressure (∼20 psi) is applied, valve will seal the channel. The third layer is glass slide to support the entire structure. All layers are bounded to each other using plasma bonding. The Integrator is a single microfluidic channel with depth 25 µm. The PDMS layer is also bounded to a glass slide; ( B ) Drawings of the oscillator and integrator ( C ) Concentration signal generation achieved by combination of valve status; ( D ) Function generated by the oscillator.

Journal: Micromachines

Article Title: Module-Fluidics: Building Blocks for Spatio-Temporal Microenvironment Control

doi: 10.3390/mi13050774

Figure Lengend Snippet: Structures of the Spatio-Temporal Concentration Controller. ( A ) 3D structure of Signal generator (Oscillator) and Module Connector (Integrator), the Oscillator consists of three layers, the PDMS structure layer has flow channels patterned. The channel is molded using positive photo resist which produces a semi-cylindrical cross-section for complete sealing of the micro valve. The second layer is a thin PDMS membrane with controlling valves when the air pressure (∼20 psi) is applied, valve will seal the channel. The third layer is glass slide to support the entire structure. All layers are bounded to each other using plasma bonding. The Integrator is a single microfluidic channel with depth 25 µm. The PDMS layer is also bounded to a glass slide; ( B ) Drawings of the oscillator and integrator ( C ) Concentration signal generation achieved by combination of valve status; ( D ) Function generated by the oscillator.

Article Snippet: All the valves are controlled by a microfluidic valve control matrix (MUX QUAKE VALVE, Elveflow) with sixteen independent pressure outlets that can provide a constant pressure input when they are switched on.

Techniques: Concentration Assay, Membrane, Clinical Proteomics, Generated